Complete and flexible system for a wide range of applications in water treatment with easy to use software and automatic recognition of sensors: available in three configurations, up to two (2), four (4) and eight (8) simultaneous measurements, freely selectable.

Equipped with two RS485 serial ports: one (1) for sensors with RS485 digital interface and MODBUS RTU protocol and one (1) opto-isolated for the connection with the communication devices (Setup Computer, Remote Control Terminals etc.) of the local networks.

Incorporates a Real Time Clock (clock with date) which allows the software to archive the data chronologically to the flash memories also used for storing LOG files of the events.

Connectable to the whole range of Chemitec digital sensors and expandable to the traditional electrodes/probes through digitizers AD Series

Measures
  • pH/ORP
  • Dissolved Oxygen
  • Conductivity
  • Turbidity
  • Suspended Solids
  • Chlorine
  • Chlorine Dioxide
  • Ozone
  • Chlorites
  • Hydrogen Peroxide
  • Peracetic Acid
  • Nitrates (ISE)
  • Nitrates (UV)
  • Organic Substances (UV)
  • Color (UV)
  • PAH*/OIL (UV-Fluorescence)
  • *Polycyclic Aromatic Hydrocarbon
  • 50 SERIES features and technical specifications

    User Interface (HMI) Programming keypad with 5 bubble-keys with • CAL Key for direct access to the Calibration menu • GRAPH/USB Key for direct access to the Measure graphs and for data download to USB PENDRIVE • MODE Key for self-recognition of sensors Graphic TFT color LCD resolution 480x272 visible area 95x93 which allows the simultaneous display of digital measurements
    Software & Functions
    Internal Data Logger (flash 64 Mbit) with possibility to store up to 250.000 records and to display stored data in tabular and graphic form. Data download to USB PENDRIVE or through RS485 and C_NET dedicated SW.

    Programmable Analog Outputs for repeating the measurements, PID control and temperature; with the first and the second set on the measurement of the same parameter, the third can be set as the average of the other two.

    Digital Output Relays to adjust the Set Points for the measures, the alarm for instrument anomaly, the probe washing or the Set Point for temperature.

    Analog Input for perturbative functions or engineered display of additional measuring.

    Digital Input for disabling of dosage.

    Display Graphic TFT color LCD
    Resolution 480 X 272 (Visible Area 95x93)
    Languages Italian, English, French, German, Spanish
    Keypad 5 bubble-keys [6] [5] single keys and [GRAPH/USB] [ESC/MODE] [ENTER/CAL] keys with double functions available
    Data logger Internal Flash 64Mbit Memory up to 250,000 records with a recording interval of 15 sec up to 120 minutes
    Recording method Circular (F.I.F.O.) or Filling
    Display of stored data In tabular and graphic form, with indication of maximum, minimum and average values of the selected period. Zoom function.
    PID Control Settable functions P [Proportional] ; PI [Proportional – Integral] and PID [Proportional – Integral – Derivative]
    Activation On analog or digital output
    Proportional range 0…500%
    Time Integral and/or derivative 0:00…5:00 min
    Analog Outputs Four (4) programmable ; 0/4…20 mA ; Galvanic separation ; 1KV Optoisolator ; Maximum load 500 Ohm ; Output limits user programmable between measuring ranges
    Alarm output NAMUR 2.4 mA (with range 4/20mA)
    Digital Outputs Six (6) ; Switching Relays usable as NO ; Maximum resistive load 3A at 230Vac
    Set Point (4) Working range setting (Hysteresis/direction) ; pause/working time setting 000…999 Seconds ; PID Control ; Pulse Frequency or PWM
    Alarm/Wash (2) Alarm: Instrument failure, min/max value, set point delay, permanence time (live check) ; Delay time ; Set Point disabling (in case of alarm): Enable/Disable
    Wash: Programmable interval (minimum 15 minuts) and duration between 00:00…24:00 hh:mm; during the washing phase, all digital and analog outputs are frozen
    Digital Inputs (2) for Free contact To disable dosing or activate wash cycle
    Power consumption 5mA max
    Serial Ports/Outputs RS485 programmable for set-up and Real Time data acquisition from remote or download stored data (using dedicated SW)
    Baud Rate 1200…38400
    Communication protocol MODBUS RTU ; on request PROFIBUS DP SLAVE, CANopen, Ethernet, Devicenet, Modbus TCP, Profinet
    Manual controls Possibility to simulate all the analogue and digital outputs using the keyboard
    Power Supply 90…240 Vac/dc 47– 63 Hz [on request 24Vac/dc]
    Transformer isolation 4KV
    Power consumption < 6W
    Electrical protection EMI / RFI CEI-EN55011 – 05/99
    Mounting Wall
    Housing material ABS Gray RAL 7045
    Dimensions (L x H x D) 144 x 144 x 122.5 mm
    Mounting depth 122.5 mm
    Mechanical protection IP 66
    Weight 1 Kg
    Operating temperature 0…50 °C
    Humidity 10…95% non-condensing
    Storage and transport -25…65 °C
    