When connected directly in the 4 to 20 mA loop, the SITRANS TR devices require no auxiliary power supply. They are installed in junction boxes or in the control room close to the process, thus permitting centralized access to all connected measurement points.

The separate auxiliary power connection ensures the great flexibility of the SITRANS TW devices in view of the output signals. For example, the SITRANS TW provides not only the most commonly used 4 to 20 mA output signal but can also be configured for 0 –20 mA and 0 –10 V or 2 –10 V via HART protocol.

We offer a range of Rail Transmitters Products.

This range includes,

  • SITRANS TR200
  • SITRANS TR300
  • SITRANS TW

  • SITRANS TR200

    SITRANS TR200 is designed to support all common RTDs, thermocouples, resistance and Millivolt sensors. Setup is quick and easy with the transmitter-modem and SIPROM T software. This configuration tool can be downloaded free. Unique user-friendly details are implemented: Without opening the 4-20mA loop, the output current can be read out directly with a multimeter. A red/green LED shows the technician the status at a glance.

    Benefits
  • Measures temperature with a linear output signal
  • High accuracy across entire ambient temperature range
  • Reduces plant noise
  • Alarm signal for sensor break or short-circuit according NAMUR 43
  • Electro magnetic compatibility (EMC) according DIN EN 61326 and NE21
  • Galvanic insulation for accuracy and safety in thermocouple applications
  • Single- or dual-point trim
  • Custom characteristic curve for application of non-standard sensors
  • Difference- and average- measurement
  • Explosion protected versions for Europe
  • Rugged design, potted electronics


  • Details
  • Input - Resistance thermometers, Thermocouples, Resistance-type sensors, DC sources
  • Output - 4 to 20 mA

  • SITRANS TR300

    SITRANS TR300 with HART- protocol is designed to support all commons, thermocouples, resistance and Millivolt sensors. Setup is quick and easy with SIMATIC PDM or handheld communicator. Unique user-friendly details are implemented: Without opening the 4-20mA loop the output current can be read out directly with a multimeter. A red/green LED shows the technician the status at a glance.

    Benefits
  • Measures temperature with a linear output signal
  • High accuracy across entire ambient temperature range
  • Reduces plant noise
  • Alarm signal for sensor break or short-circuit according NAMUR 43
  • Electro magnetic compatibility (EMC) according DIN EN 61326 and NE21
  • Galvanic insulation for accuracy and safety in thermocouple applications
  • Single- or dual-point trim
  • Custom characteristic curve for application of non-standard sensors
  • Difference- and average- measurement
  • Extensive diagnosis: e.g. drag indicator and time meter
  • Set of output current for simulation
  • Explosion protected versions for Europe
  • Rugged design, potted electronics


  • Details
  • Input - Resistance thermometers, Thermocouples, Resistance-type sensors, DC sources
  • Output - 4 to 20 mA, HART

  • SITRANS TW

    SITRANS TW is a consistent further development of the hundred thousand times proven SITRANS T for the 4wire system in the mounting rail housing. Its many new functions set new standards in temperature transmitters. Its diagnostic and simulation functions provide the necessary clarity during commissioning and operation. Its HART®-interface makes the SITRANS TW easily adaptable to any measuring job with SIMATIC PDM.

    Physical values can be preset with the simulation function. This enables testing of the complete signal path right as far as the control system without the need for tools. The drag pointer functions measure the system’s process variable minimum and maximum. All SITRANS TW control room devices are available in non-intrinsically safe versions and intrinsically safe versions for applications under extreme conditions.

    Benefits
  • Explosion protection [EEx ia] or [EEx ib] for measurements with sensors in the hazardous area
  • Temperature-linear characteristic for all temperature sensors
  • Temperature-linear characteristic can be selected for all temperature sensors
  • Diagnostic functions
  • Slave pointer functions


  • Details
  • Input - Resistance thermometers, Thermocouples, Resistance-type sensors, DC sources, Current sources
  • Output - 0/4 to 20 mA, HART | 0/2 to 10 V, HART
  • 