MASS 2100 DI 3 to DI 40 is suitable for accurate mass flow measurement of a variety of liquids and gases.
The sensor offers superior performance in terms of flow accuracy, turn-down ratio and density accuracy. The ease of installation through a "plug & play" mechanical and electrical interface ensures optimum performance and operation.
The sensor delivers true multi-parameter measurements i.e.: Mass flow, volume flow, density, temperature and fraction.
Benefits
High accuracy better than 0.1 % of mass flow rate
Large dynamic turn-down ratio better than 500:1
Densitometer performance available through density accuracy (depending upon sensor size) ranging from 0.0005 to 0.0015 g/cm3 with a typical repeatability better than 0.0001 to 0.0002 g/cm3
Single continuous tube design, with no internal welds, reductions or flow splitters offers optimal hygiene, safety and CIP cleanability for food and beverage and pharmaceutical applications
Markets’ thickest sensor walls ensure optimal life-time and corrosion resistance and high-pressure durability
Full bore design provides lower pressure loss due to same internal diameter throughout the entire sensor
Balanced pipe design with little mechanical energy loss, ensures optimal performance and stability under non-ideal and unstable process conditions (pressure, temperature, density changes etc.)
4-wire Pt1000 temperature measurement ensures optimum accuracy on mass flow, density and fraction flow
Multi-plug electrical connector and SENSORPROM enables true "plug & play". Installation and commissioning in less than 10 minutes
Intrinsically safe Ex design ia IIC as standard, making service in hazardous area possible without having to demount the sensor if a compact Ex d transmitter needs service
Sensor pipe available in high-quality stainless steel AISI 316L/1.4435 or Hastelloy C22/2.4602 offering optimum corrosion resistance
Centre-block design decouples process noise from the environment such as vibrations, pulsations, pressure shocks etc. making installation flexible and versatile
Rugged and space-saving sensor design in stainless steel matching all environments
High-pressure program as standard
The sensor calibration factor is also valid for gas measurement
Uniform sensor interface matching all transmitter versions at the same time whether it is compact IP67/NEMA 6, compact Ex d or remote installation, one sensor fits all
MASS 6000 is based on digital signal processing technology –
engineered for high performance, fast flow step response, fast
batching applications, high immunity against process noise,
easy to install, commission and maintain.
The MASS 6000 transmitter delivers true multiparameter measurements
i.e. mass flow, volume flow, density, temperature and
fraction.
The MASS 6000 IP67 transmitter can be compact mounted on all
sensors of type MASS 2100 DI 3 to DI 40, and can be used in
remote version for all types of MASS 2100/MC2 and FC300 sensors.
Benefits
Dedicated mass flow chip with the latest ASIC technology
Fast batching and flow step response with an update rate of true 30 Hz
Superior noise immunity due to a DFT (Discrete Fourier Transformation) algorithm.
Front end resolution better than 0.35 ns improves zero point stability and enhances dynamic turn-down ratio on flow and density accuracy
Advanced diagnosis and service menu enhances troubleshooting and meter verification.
Built-in batch controller with compensation and monitoring comprising 2 built-in totalizers
Multi-parameter outputs, individual configurable for mass flow, volume flow, density, temperature or fraction flow such as Brix or Plato
Digital input for batch control, remote zero adjust or forced output mode
All outputs can be forced to preset value for simulation, verification or calibration purposes
User-configurable operation menu with password protection
- 3 lines, 20 characters display in 11 languages
- Self-explaining error handling/log in text format
- Keypad can be used for controlling batch as start/stop/hold/reset
SENSORPROM technology automatically configures transmitter at start-up
The complete flowmeter system SITRANS FC430 can be ordered
for standard, hygienic or NAMUR service. All versions can
be ordered for CT service, according to OIML R 117 (Liquids
other than water).
SIL specified compact variants can be validated and configured
for SIL 2 or SIL 3 operation. SIL 3 operation requires two flowmeters
in series and monitored by a SIL-rated control system. Series
mounting must not introduce cross-talk between the sensors.
Refer to installation guidelines.
The flowmeter is based on the latest developments within digital
signal processing technology – engineered for high measuring
performance:
FCT030 is based on the latest developments within digital signal
processing technology – engineered for high measuring performance,
fast response to step changes in flow, fast dosing applications,
high immunity against process noise, easy to install
commission and maintain.
The FCT030 transmitter delivers true multi-parameter measurements
i.e. massflow, volumeflow, corrected volumeflow, density,
temperature and fraction.
The FCT030 IP67 transmitter can be remote connected or compact
mounted with all sensors of type FCS400, sizes DN 15 to DN80.
Benefits
Flow calculation and measurement
Dedicated mass flow calculation with DSP technology
Fast dosing and flow step response with maximum 10 ms response time
100 Hz update rate to all outputs
Maximum data age from pickup to output is 20 ms (two update cycles)
Independent low flow cut-off settings for mass and volume flowrates
Automatic zero-point adjustment on command from discrete input or host system
Empty pipe monitoring
Operation and display
User-configurable operation display
Full graphical display 240 x 160 pixels with up to 6 programmable views
Self-explaining alarm handling/log in clear text
Help text for all parameters appears automatically in the configuration menu
Keypad can be used for controlling dosing as start/stop/hold/reset
SensorFlash technology stores production specific system documentation
Provides removable memory of all flowmeter setups and functions
Calibration certificates
Pressure and material test certificates (as ordered)
Non-volatile memory backup of operational data
Transfer of user configuration to other flowmeters